High Torque Soft Start Motor Starter Asynchronous Motor Built - In Bypass

Brand Name : Noker

Model Number : NK300-J3-160-G

Certification : CCC

Place of Origin : China

MOQ : 1 Set

Price : Depend on quantity

Payment Terms : L/C, T/T, Western Union

Supply Ability : 1000 set per month

Delivery Time : 5-8 work days

Packaging Details : Carton Packaging

Size : Compact Size, Light Weight

Display : LED display

Reliability : High reliability

Stop mode : Soft stop

Operation : Simple operation

Protection : Perfect protection

Contact Now

High Torque Asynchronous Motor Electronic Soft Starter Built-in Bypass

NK300 series all-digital AC motor soft starter is a new type of starting equipment which is designed and produced by using power electronics technology, micro-processing technology and current control theory. The product can effectively limit the starting current in the starting process of asynchronous motor, can be widely used in fan, water pump, transportation and compressor and other loads, is a Ideal replacement products of traditional starting equipment such as star/triangle conversion, auto-Coupling and Magnetic-Controlled starter.

Features

1. In terms of performance and quality, it has reached the level comparable to imported advanced brands

2. Upgrading of common domestic soft starters and the ideal alternative to imported products

3. The functions and performance indicators have been carefully designed and tested

4. Parameters are easy to set up and easy to debug

5. Intelligent motor soft starter, protection function

6. A variety of starting methods can be used to meet the starting requirements of various loads

7. Power frequency, phase sequence adaptive function

8. Built-in current transformer, no additional configuration required

9. 4-20mA analog current real time output function

10. Fault information storage function

11. Perfect motor protection function to maximize the safety of the use of the motor

12. All signals are optoelectronic isolation, which has strong anti-interference

Comparison of Start Mode

High Torque Soft Start Motor Starter Asynchronous Motor Built - In Bypass

Terminal Description

Terminal No. Name of terminal Description

Main circuit

R,S,T Power Supply terminal Connect to Power supply
L11,L12,L13 Bypass terminal Connect to Bypass contactor
U,V,W Motor terminal Connect to motor

Control circuit

1 Bypass output Bypass output
2
3 Time-delay output Time-delay output
4
5 Failure output Failure output
6
7 Instantaneous stop Instantaneous stop
8 Stop Stop disconnect to Public, then stop
9 Start-up Start-up connect to Public, then start
10 Public Public
11 Analog output - 4-20mA
12 Analog output +

Specification

Item Description
Power supply AC220V/380V/660V±15%
Power frequency 50/60Hz
Adaptive Motor Squirrel-cage three-phase asynchronous motor
Starting times It is recommended not to exceed 20 times per hour
Control mode

1) Operation panel control;
2) Operation panel +external control;
3) External control ;

4) External control+ COM control ;
5) Operation panel +external+ COM control;
6) Operation panel + COM control;

7) COM control ;
8) No start or stop operation;

Start Mode

1) Current-limiting start;
2) Voltage ramp start;
3) Torque control +current-limiting to start;

4) Torque control +voltage ramp to start;
5) Current ramp to start;
6) Voltage current-limiting double closed-loop start;

Stop Mode 1) Soft stop;
2) Free stop;

Protective Function

1) Open loop protection for external instantaneous stop terminals;

2) Over-heat protection for soft starter;
3) Protection for too long starting time;

4) Input open phase protection;
5) Output open phase protection;
6) Unbalanced three-phase protection;

7) Starting over current protection;
8) Running overload protection;
9) Under voltage protection for power voltage;

10) Overvoltage protection for power voltage;
11) Protection for fault parameter setting;
12) Load short circuit protection;

13) Auto restart or incorrect wiring protection;
14) Incorrect wiring protection of external control stop terminals;

Protection Class IP00,IP20
Cooling Pattern Natural wind cooling
Place to be used Indoor location with good ventilation free from corrosive gas and conductive dust.
Environment Condition Below 2000M. Rise the rate power when the altitude is more than 2000M.
Ambient Temperature -25+45°C
Ambient Humidity 95%(20°C±5°C)
Vibration<0.5G


Maintenance


1.Dust: If too much dust, it will reduce the insulation level of the soft starter, even causes the soft starter does not work.
Brush the dust with clean and dry brush.
Remove dust with compressed air machine.
2. Condensation: If condensation, it will reduce the insulation level of soft starter, even causes the soft starter does not work.
(1) Blow it with a hair dryer or electric stove.
(2) Bring it to power distribution room for dehumidification.
3. Regularly check components' intact. Whether it can work properly.
4. Check soft starter' cooling channel, ensure they are not clogged by dirt and dust.
Before maintenance checking, it has to cut off all power in the line side of soft starter.

Shipemt and Packaging

High Torque Soft Start Motor Starter Asynchronous Motor Built - In Bypass


Product Tags:

scr soft starter

      

thyristor soft starter

      

3 phase soft starter

      
China High Torque Soft Start Motor Starter Asynchronous Motor Built - In Bypass wholesale

High Torque Soft Start Motor Starter Asynchronous Motor Built - In Bypass Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Noker Electric Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0